Measurement accuracy, configurable measurement display, parallel measurement options, intuitive operation, sturdy housing, connection option to the testo Smart App: Our flue gas analyzer testo 310 II offers everything that heating fitters and technicians need for practical work on heating systems.
Reliable testing of heating systems with the flue gas analyzer testo 310 II for beginners
The compact flue gas analyzer offers, in addition to the simple user interface, menu navigation with four integrated measurement menus for flue gas, draught, ambient CO and pressure. All measurement results are visible at a glance in the display and can even be configured, thanks to the high-resolution graphic display.
If needed, you keep your hands are free during the measurement - because the flue gas analyzer testo 310 II can be fixed to metal surfaces, e.g. the burner, using the magnets on the back of the instrument. But this is not the only practical feature: The testo Smart App allows you to operate and configure your instrument via the remote function.
The robust design for harsh, dirty environments, the fast sensor zeroing in 30 seconds, the easily replaceable probe filter and the condensate trap that can be emptied quickly make the flue gas analyzer the optimal tool for plant mechanics because it is cleverly designed.
If required, the measurement results can be transferred to the optionally available Testo quick printer via Bluetooth® interface or sent by e-mail and printed out directly on site.
Easy and intuitive menu guidance
Simultaneous, additional measurements via the testo Smart App
Simultaneous, individual measurement and display of all relevant measurement parameters by (O2, CO, CO2, flue gas and ambient temperature, CO environment, draught and pressure)
Digital documentation, data transfer and customer data management via testo Smart App
Flue gas analyzer testo 310 II incl. rech. battery and calibration protocol for the measurement of O2, CO, hPa and °C, probe 180 mm with cone, silicon hose for pressure measurement, particle filters 5 off. and case
Measuring range | -20 to +400 °C |
---|---|
Accuracy | ±1 °C (-20 to +100 °C)
±1.5 % of mv (> 100 °C) |
Resolution | 0.1 °C |
Reaction time | < 50 s |
Measuring range | 0 to 21 Vol.% |
---|---|
Accuracy | ±0.2 Vol.%
|
Resolution | 0.1 Vol.% |
Reaction time | 30 s |
Measuring range | -20 to +20 hPa |
---|---|
Accuracy | ±1.5 % of mv (Remaining Range)
±0.03 hPa (-3.00 to +3.00 hPa)
|
Resolution | 0.01 hPa |
Measuring range | 0 to 120 % |
---|---|
Resolution | 0.1 % |
Measuring range | -0 to 99.9 % |
---|---|
Resolution | 0.1 % |
Measuring range | -40 to +40 hPa |
---|---|
Accuracy | ±0.5 hPa
|
Resolution | 0.1 hPa |
Measuring range | 0 to 4000 ppm |
---|---|
Accuracy | ±10 % of mv (2001 to 4000 ppm)
±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
|
Resolution | 1 ppm |
Reaction time | 60 s |
Measuring range | 0 to 4000 ppm |
---|---|
Accuracy | ±10 % of mv (2001 to 4000 ppm)
±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
|
Resolution | 1 ppm |
Reaction time | 60 s |
Weight | Approx. 660 g |
---|---|
Dimensions | 201 x 83 x 44 mm |
Operating temperature | -5 to +45 °C |
Display function | Graphic 7-line display |
Power supply | Battery: 1500 mAh, mains unit 5V/1A |
Storage temperature | -20 to +50 °C |